Jul 5, 2011 5:46 PM

Error de Inicialización de POD HD500

Mi POD repentinamente comenzó a tener problemas en su inicialización luego de utilizar el programa POD HD500 Edit. Comenzó a dar un error, y en la imagen de la conexión entre el POD y el EDIT desde la interfaz gráfica, comenzó a titilar un símbolo cuya leyenda era 'Input'.

 

Luego de eso, el POD empezó a reiniciarse, mostrar el logo de LINE 6, y reiniciarse nuevamente, y así sucesivamente.

 

No se qué hacer.

 

Podrían ayudarme?

 

Gracias y saludos,

 

Federico

  • laplayantonio Guru 2,435 posts since
    Sep 26, 2006
    Currently Being Moderated
    Jul 6, 2011 3:18 AM (in response to felicetche)
    RE: Error de Inicialización de POD HD500

    hola Federico

       

      intenta reinstalar el Firmware de tu HD500: http://line6.com/community/docs/DOC-2300  ("Q:  How do I perform a Factory Reset on the POD HD500?")

       

      si esto no arregla tu problema, contacta tu vendedor Line6 para utilizar la garantia: http://line6.com/community/docs/DOC-1712

       

       

      line6antonio

  • tommasi Iknowathingortwo 627 posts since
    Sep 3, 2007
    Currently Being Moderated
    Jul 6, 2011 3:19 AM (in response to felicetche)
    Re: Error de Inicialización de POD HD500

    Check this thread out, it may be of help.

     

    http://line6.com/community/thread/66777

      • tommasi Iknowathingortwo 627 posts since
        Sep 3, 2007
        Currently Being Moderated
        Jul 7, 2011 12:42 PM (in response to felicetche)
        Re: Error de Inicialización de POD HD500

        Actually the first thing I'll try is a "factory reset" (doesn't affect your patches). First of all disconnect everything from the pod. Then:

         

        power up the unit while holding the left directional pad pressed.

         

        the unit should go to default patch 1A -- unless that's the bad patch, you should be alright. You should then try to connect edit and get rid of the bad patch, if you know which one the unit was on when it started behaving like this. When you do a factory reset, the global parameters are overwritten (output mode, footswitch mode etc. and you need to rese them).

         

        If you don't know which patch was bad, you can reflash the firmware; to start in safe mode, power up while holding the RIGHT pad pressed. Then connect to a PC and reflash overwriting everything. You'll lose all your patches unless you have backed them up -- if you don't overwrite the patches the problem will persist.

  • laplayantonio Guru 2,435 posts since
    Sep 26, 2006
    Currently Being Moderated
    Jul 8, 2011 1:29 AM (in response to felicetche)
    RE: Error de Inicialización de POD HD500

    lo dicho: si no puedes iniciarlo en 'safe mode' para reflashearlo, entonces utiliza por favor tu garantía

       

      un saludo

       

      line6antonio

  • Josuen22 Just Startin' 2 posts since
    May 20, 2012
    Currently Being Moderated
    Jun 1, 2012 5:07 PM (in response to felicetche)
    Re: Error de Inicialización de POD HD500

    fijate q yo lo aregle presionando  flecha y ya se ereglo espero q te ayude

  • Josuen22 Just Startin' 2 posts since
    May 20, 2012
    Currently Being Moderated
    Jun 1, 2012 5:08 PM (in response to felicetche)
    Re: Error de Inicialización de POD HD500

    yo  lo compuse presionando un tiempo la flecha iquierda y q reset yya estuvo espero q te ayude  y si no se te compone es mejor tu garantia  espero ayudarte