Dec 13, 2011 4:56 AM
How to calibrate hd pod 300
-
Like (0)
Hi thre guys!
I'm trying to calibrate my hd pod 300, but after see these video http://www.youtube.com/watch?v=dg2cJ0QNDeA, I still have a probelm. Which one is the pedal toe switch?? I did as the video ask me to do, but nothing happen
Plus!
If I use the pedal volume and push till the the wah doesn't work.
I'm new with this stuff, so
And advice???
Thanks Very Much
Like a Crybaby....Line 6 toe switches can be a little stiff when new...put some wieght on it...It should break in after a bit...
You need to apply a LOT of pressure to activate the toe switch until it loosens up. You usually can't do it sitting down - need to stand on it.
POD HD 300 & 400 pedal calibration:
-After performing a manual reset on the unit press the D channel footswitch
-Press down on the expression pedal until the switch clicks
-Push the expression pedal fully to the heel down position
-Press the D channel footswitch
-Push the expression pedal fully to the toe down position
-Press the D channel footswitch
-Sweep the pedal to check the values (should be from 0 to 127 for full sweep)
-Press the D channel footswitch to save
if needed, please stand up and use your body weight to actuate the pedal toe switch
line6antonio
You also have to "enable" the wah in the patch or it won't work no matter how hard you mash on the switch.Not all patches have the wah enabled.
Stay in the mix and in the know.