Hardware: Helix LT
Firmware/Editor: Firmware 3.80 (build 7d01f5e), HX Edit 3.80
OS: macOS Sonoma on MacBook Pro M2 (no hub, direct USB-C to USB-A adapter)
Global Settings: Snapshot Edits = Recall
Attach Preset: Can upload .hlx test file if needed
Bug description:
When changing a parameter (e.g., Drive, Channel Volume) in the Amp block between two snapshots, Helix does not store the values individually per snapshot.
After saving, both snapshots retain the same value — always the last one edited.
Steps to reproduce:
Create a brand new preset
Insert a single Amp block (e.g., Brit Plexi Brt)
Go to Snapshot 1 → Set Drive to 5.0
Save the preset
Go to Snapshot 2 → Set Drive to 7.0
Save again
Switch back to Snapshot 1 → Drive is now also 7.0, not 5.0
Same happens with Channel Volume or any other amp parameter.
Additional notes:
No controller assignments are present (confirmed via HX Edit and on-device)
Volume/Pan block was also tested but its Gain parameter is not snapshot-compatible (expected)
Same behavior occurs with other amp models
Factory Reset has been performed (FS 9+10)
Bug still occurs with absolutely clean preset
HX Edit and firmware both up to date (v3.80)
Snapshot Edits setting is correctly set to Recall
Please confirm if this is a known bug in version 3.80 or if anyone has found a reliable workaround (other than duplicating amp blocks per snapshot).