Search the Community
Showing results for tags 'loading'.
-
M5 Backup Procedure: With a MIDI interface and a sysex application, you can back up all your M5 presets to your computer. This makes it easy to build a custom preset library, or exchange presets with others. To backup your presets, or to dump the current preset, follow these steps: 1. Turn bottom left PARAMETER KNOB to set your MIDI Channel (Ch. 1-16 or Omni - the default is Ch. 1). 2. Turn the Model Select knob to select DUMP ALL? (to back up all 24 presets) or DUMP PRE? (to back up your current preset). NOTE: There is an error in the M5 Pilot Guide.pdf regarding the following step in the SysEx dump procedures. Please refer to the information here for correct behavior: 3. With your computer set up to record sysex, press and hold ON/OFF while you press down on the MODEL SELECT knob. Repeat this to confirm or press TAP to exit out, if you choose. 4. The M5 will immediately transmit the sysex file to your computer, creating a backup of your Scenes that you can store and recall at any time. To load presets back into your M5, simply transmit the sysex file from your computer into the M5 via MIDI. This will immediately load the data into the M5's memory.
-
Hi, I just bought an HX Stomp. Downloaded my first IR and was trying them out. Just for fun, I cleared them to try new ones and now I'm having problem transferring IR to my unit, even the same IR i was already using. My HX Stomp stays "blocked" saying Transferring Data... and my soft is also blocked. I tried changing USB Ports, not using a hub, any possible combination and it's driving me crazy. I even reset everything and still doesn't work. Could it be a faulty unit? Thanks in advance for your help
-
M5/M9/M13 BACKUP INSTRUCTIONS *** This procedure is also explained in the M9 Advanced User's Guide and M13 Advanced User's Guide REQUIRED: A MIDI sequencer app such as Cubase or a sysex app -- if you don't have a sysex app installed, do a Google search for MIDI Ox (Windows) or Sysex Librarian (Mac) then download one or the other and install it. And ONE of the following: A MIDI interface that connects to your computer via USB (download the current Driver for it if you don't have it installed) & 2 MIDI cables OR A MIDI - USB interface such as the M-Audio Uno that comes with attached MIDI cables. You may need to download & install the latest driver from the manufacturer for this device. When your MIDI interface, Driver and sysex app are ready to go, follow PROCEDURE instructions below. Windows: Saving Scenes & Folders: 1. Run MIDI OX. You can do so from Start > Program Files > MIDI OX. 2. Set "Pass Sysex" & "Start Display" to On by clicking on the the 'REC' & 'SYX' boxes at the bottom right of the main window so it is highlighted blue. 3. Now go to View > Sysex. A Sysex View and Scratchpad window will open. 4. Go to the Sysex menu & select "Receive Manual Dump." When selected, you will see a window appear waiting on info from the M9/M13. 5. In Setup Menu of M9 (Press the 1B and 2B buttons at once, then press the MODEL SELECT knob 3 times until the display shows MIDI in the top left) or the M13 (hold the 'Looper Controls' button), select 'Dump All' to backup all your scenes, 'Dump Folder' to backup the current folder, or 'Dump Edit' to backup the one scene you have currently selected. Press the TAP button and the 'MODEL SELECT' knob at the same time on the M9 or just press the 'MODEL SELECT' knob on the M13 to begin the dump. Click 'Done' in MIDI OX when complete. 6. Under the 'Display Window' of MIDI OX, click 'Save As' and save it as a Sysex file type. Loading Scenes & Folders: 1. Run MIDI OX 2. Go to View > Sysex. A Sysex View and Scratchpad window will open. 3. Under the 'Command Window' menu, select 'Load File' and select the Sysex scene or folder file that is saved on your computer. If you are attempting to load an individual scene, it will be recalled to your current scene location, so change to the scene location on the M9/M13 you would like to overwrite. 4. Again, go to the 'Command Window' menu & select 'Send/Rec Sysex.' The display on the M9 (FX Unit 4 on the M13) will flash 'Receiving MIDI - Standby.' Once complete, your scene(s)/folder are now loaded. You do not have to set anything on the M9/M13, it will simply load the individual scene to the current location or load all the scenes in one shot once it receives the file. If you are loading a folder, it will load to the same folder location that it originated from. So, if you saved Folder 3 from the M9/M13, it will load back into the Folder 3 location on the hardware regardless of which Folder you may be looking into. **Note - Using 'Send Sysex' does not work. MIDI OX screen will read 'Sysex Receive' although it is sending to the M9/M13. MAC USERS: Saving Scenes & Folders: 1. Open Sysex Librarian. 2. You should already see your MIDI interface (or 'USB Uno MIDI Interface') listed in the dropdown menu at the top. If not you will need to download & install the latest drivers available from the manufacturer. 3. Click the 'Record Many' button. Use this even when backing up an individual scene. A window will appear showing it is awaiting info from the M9/M13. 4. On the M9/M13 select either 'Dump All' (all scenes), 'Dump Folder' (current folder), or 'Dump Edit' (current scene). Press the TAP button and the 'MODEL SELECT' knob at the same time on the M9 or just press the 'MODEL SELECT' knob on the M13 to begin the dump. 5. Once complete, you can rename 'untitiled.syx' in Sysex Librarian by clicking the name once it is highlighted. Loading Scenes & Folders: 1. Select the Sysex file you wish to load. 2. Click 'Play'. You will see 'Receiving MIDI - Standby' in the display on the M9 (FX Unit 4 on the M13). Your scene(s)/folder is now loaded. Again, if you are loading an individual scene, it will load to the current location you are in, so select the scene you wish to overwrite BEFORE loading the backup file. If you are loading a folder, it will load to the same folder location that it originated from. So, if you saved Folder 3 from the M9/M13, it will load back into the Folder 3 location on the hardware regardless of which Folder you may be looking into. M5 Backup Procedure: With a MIDI interface and a sysex application, you can back up all your M5 presets to your computer. This makes it easy to build a custom preset library, or exchange presets with others. To backup your presets, or to dump the current preset, follow these steps: 1. Turn bottom left PARAMETER KNOB to set your MIDI Channel (Ch. 1-16 or Omni - the default is Ch. 1). 2. Turn the Model Select knob to select DUMP ALL? (to back up all 24 presets) or DUMP PRE? (to back up your current preset). NOTE: There is an error in the M5 Pilot Guide.pdf regarding the following step in the SysEx dump procedures. Please refer to the information here for correct behavior: 3. With your computer set up to record sysex, press and hold ON/OFF while you press down on the MODEL SELECT knob. Repeat this to confirm or press TAP to exit out, if you choose. 4. The M5 will immediately transmit the sysex file to your computer, creating a backup of your Scenes that you can store and recall at any time. To load presets back into your M5, simply transmit the sysex file from your computer into the M5 via MIDI. This will immediately load the data into the M5's memory.
-
Hi, I have a problem with my Pod HD. While trying to connect it to my computer, I accidentaly touched the footswitch's cable slot with my USB cable and after that my POD's screen started to glitch, working only half of it and went to an infinite loop so wont reboot properly. It just keeps loading and rebooting. If i leave it a while, the screens starts working but stays at the Line6 logo going on and off. I've already tried turning it on while pressing the left nav but nothing happens. If I put on the flash update mode (down nav) it will glitch at first but then it will appear "Update flash" on the screen, but my computer wont cognize it anyway. NOTE: While uploading the video, the screeen stopped glitching, but the unit won start, it just keeps loading. Help...
-
Hi all I have a line 6 Amplifi 175 amp and I thoroughly enjoy it. However one of its features are really starting to annoy me. I'm trying to disable the function where when I start playing a song from my library, a list of suggested tones drops down and it automatically switches to the first one. I really want this to stop. I find some other tones that are available are so much better than the ones that are suggested, but when I pause the song to go switch to the tone that I want and go to un-pause the song again, it switches the suggested tone again. I've switched off Auto tone loading in the options menu on the remote app and it will still do it. Does anyone know how to permanently disable the auto tone load function when I play a song?
-
Hi I purchased the vintage amp pack a couple of weeks ago. Due to a busy Schedule I hav just now gotten around to installing this. I followed all the instructions. Updated drivers and software with the Monkey. (I can see the clobal eq) with License manager I authorized my computer. I can now see the Vintage amp pack in the License manager. I then Authorized my HD500x And clicked INSTALL. The dialog box "recycle power...." appears. BUT no Vintage Amp pack to be seen either in the Licensemanager or on the HD500x itself - (Standard model set - under Amp pack) I tried to unauthorize my HD500x and authorize Again - no success Please advice - Thanks Kind regards Bendt Aaen