Please ensure Javascript is enabled for purposes of website accessibility Jump to content

Search the Community

Showing results for tags 'restore'.

  • Search By Tags

    Type tags separated by commas.
  • Search By Author

Content Type


Forums

  • Community Support
    • Multi-Effects Units
    • Variax Instruments
    • Amplifiers
    • Computer Based Recording
    • Live Sound
    • Pedals/Controllers
    • Dream Rig - Line 6 Product Integration
  • General Discussion
    • Tone Discussion
    • Line 6 Lounge

Categories

  • General FAQ
    • Operating System-specific Information
  • Tutorial Videos
  • Effects/Controllers
    • HELIX/HX
    • DL4 MkII Stompbox Modeler
    • FBV Controllers (MKII / 3)
    • M5
  • Amplifiers
    • Powercab
    • Catalyst
    • Spider V
  • POD
    • POD Go
    • Pocket POD
    • POD Express
  • Guitars
    • JTV / Shuriken / Variax Standard / Workbench HD
  • Relay/XD-V Digital Wireless
  • Recording
    • Helix Native
    • Metallurgy
    • Echo Farm/Amp Farm
    • POD Farm 1/2.0/2.5
    • Computer Audio Set Up and Troubleshooting
  • Legacy Products
    • POD
    • Amps
    • 1st Gen Variax Guitars / Bass / Workbench
    • Effects and Controllers
    • AMPLIFi Series
    • Live Sound
    • Digital Wireless
    • Mobile Products
    • POD Studio / Tone Port / GuitarPort
    • Software
    • Dream Rig

Find results in...

Find results that contain...


Date Created

  • Start

    End


Last Updated

  • Start

    End


Filter by number of...

Joined

  • Start

    End


Group


AIM


MSN


Website URL


ICQ


Yahoo


Jabber


Skype


Location


Interests


Registered Products

Found 7 results

  1. Note: This will erase all current presets and restore the factory sounds, so please save your sounds on a second source if necessary. AMPLIFi 30/75/150/TT: Press and hold the Master Volume knob and Tone button as you power up the amp. AMPLIFi FX100: Press and hold the Master Volume knob and the TAP button as you power up the unit. Axsys 212 or AX2: Press and hold the "User/Preset" and "Save/Store Sounds" buttons, and keep holding as you turn the unit on. Catalyst: Hold down the CH B and MANUAL buttons on the front panel of your CATALYST while powering on the amplifier. DL4: You can reset your pedal to the factory settings by powering it up with the A and D footswitches held down - the power is turned on and off on the modeler pedals by inserting a plug into the left mono input jack. DL4 MKII: Hold down footswitch A and TAP while inserting the power connector and powering on. Duoverb: Hold A & D while powering unit. DT25/DT50: Requires a MIDI-to-USB interface with driver support from manufacturer (M-Audio MIDIsport series, Yamaha UX16, etc.) and use Line 6 Monkey via USB connection to MIDI In and MIDI Out of DT50 for a firmware re-install. DT25/DT50 Firmware Update Instructions Firehawk FX: Press and hold the Master Volume knob and the TAP button as you power up the unit. Unfortunately, any patches not backed up to My Tones prior to the reset will be lost. Firehawk 1500: Press and hold the Master Volume knob and the Navigation Encoder (the scroll wheel) as you power up the unit. Flextone I &II: hold down A, B, C, and D while powering the unit on. Flextone III: hold the A and D Buttons while powering up for 8 seconds. Bass POD: press and hold the up and down arrow buttons as you power the unit on for ~ 5-7 seconds or until it goes to the preset 1-A Bass POD Pro: Hold the UP and DOWN arrow key down as you power on for ~ 7 seconds. Bass POD XT Pro and Bean: press SAVE once, use the select key to scroll clockwise to the factory recall page, then press SAVE twice. Bass POD XT Live: see POD XT Bean/Live/Pro Bass Floor POD: Hold COMP and FX while powering up. When 01 appears, disconnect power. Power up. Floor POD: Hold MOD and DELAY while powering up. When 01 appears, disconnect power. Power up. Floor POD Plus: Hold BANK UP and BANK DOWN while powering up unit (display will read INT) Four Button Modeling Pedal: (DL-4, MM-4, FM-4, DM-4): Hold A and D footswitches and power up - the power is turned on and off on the modeler pedals by inserting a plug into the left mono input jack. Helix Floor/LT: Turn unit off and then back on. Hold in Footswitches 9 and 10 right after you turn the unit on, throughout the boot process, until you see that your factory presets are loading. Helix Rack: Turn unit off and then back on. Hold in Encoders 5 and 6 right after you turn the unit on, throughout the boot process, until you see that your factory presets are loading. HX Effects: Turn unit off and then turn back on. Hold Footswitch 6 and Tap throughout the boot process, until you see that your factory presets are loading. If you run into any trouble with a failed update or your unit will not boot up, try powering on while holding the right arrow ">" This will put the unit into update mode and you can re-install the latest firmware from there. HX Stomp: Turn unit off and then turn back on. Hold Footswitches 2 and 3 as the unit boots up. HX Stomp XL: Turn unit off and then turn back on. Hold Footswitches C and D as the unit boots up. HX One: Hold down the Effect Knob and Home button while inserting the power connector and powering on. HD147: hold the A and D Buttons while powering up your amp. JM4: Hold down the settings/tone button as you power the unit on and hold the button for 5-8 seconds. M5: Press and hold the TAP button and tap the Model Select knob to enter the setup menu. Tap the model select knob until you see the MIDI, Tempo and Gate functions. Turn the model select knob until the corresponding display shows RST FACT. Hold the On/Off switch and tap the model select knob twice to reset the M5. M9: Press FX Unit 1B and 2B switches at the same time to enter the setup menu. Press the Model Select knob until the display reads MIDI Gate Display across the top. Turn the Model Select knob until the corresponding display shows RST FACT. Press and hold the TAP button just before (split second) pressing the Model Select knob. Its like pressing them down at the same time, but making sure the TAP button is pressed first. Do that once again to reset the M9. M13: Press and hold Looper Controls to enter the setup menu. In FX UNIT 4, turn the Model Select knob until the corresponding display shows RST FACT. Press down on the Model Select knob twice to complete the reset. Lowdown: power on while holding down the 'A' button for 5-8 seconds. POD/POD 2.0/Bass POD/POD Pro: press and hold the up and down arrow buttons as you power the unit on for ~ 5-7 seconds or until it goes to the preset 1-A Pocket POD: Hold the save button and 4-way arrow key up while plugging a cable into the instrument input to power the unit on. The unit will prompt for a factory reset, press save to initiate the factory reset. You can also re-install the flash memory on the Pocket POD by connecting to your computer via USB and using the latest version of Line 6 Monkey. In the UPDATES tab of Monkey, click on Flash Memory, then click 'Re-Install Latest' or 'Update Selection'. POD X3 - Bean/Live: Press and hold the "Home/Hold For Commands" button, select "Reset User Presets" and press the "Save" knob to reset the User bank to its factory presets. POD XT: Bean/Live/Pro: You must re-install the flash memory on the PODxt device to reset the unit back to factory settings. Check out this link for instructions. PODxt reflash instructions. POD HD300/400: POD HD300/400 Factory Reset Video Tutorial POD HD500/500x/HD/HD Pro: You must re-install the flash memory on the HD device to reset the unit back to factory settings. Check out this link for instructions POD HD500 Factory Reset Video Tutorial POD GO: Hold Buttons C and D as you power up the unit. POD Express or POD Express Bass: Start by powering POD Express off and disconnecting any USB cable. While holding both the ON and TAP footswitches, power on the device: • If using batteries, connect a 1/4" cable into the device's IN jack to power on. • If using a power adapter, connect the adapter to the DC IN to power on. When powering on the device, you’ll see all the AMP encoder’s LEDs flash white briefly three times indicating the factory reset was successful. Powercab 112 Plus: Re-flashing the firmware will effectively perform a factory reset. Rackmounted Pro Effect units MOD Pro/Filter Pro/Echo Pro: press MIDI/Sys, use program select knob to FR (save button will begin flashing). Turn speed knob all the way up to "all", press save twice. Relay G70/75 From the edit menu, select "Factory Reset" and press the Nav/Select Encoder. Turn the Encoder to select OK, or cancel to exit. Press the encoder button to commit your selection. Spider I, II, III, IV, Micro, and Valve Series: Hold down the A (or clean) button as you turn on the power and hold the button for 5-8 seconds. Spider V Hold down the Home button to access the settings menu. Scroll down with the encoder to where it say Factory Reset. Scroll to the right and press to encoder knob to hit Yes. Spider V 20: Hold down FX2 and FX3 buttons while powering on, then press and release 'save' while the amp is turned on. Spider Jam: Hold down the settings/tone button as you turn on the power and hold the button for 5-8 seconds. Stagescape M20d: You must tap the "i" button in the upper right corner of the Main Toolbar. Then tap Show System Settings > backup > Restore Factory Settings. **Warning!** This procedure will erases ALL stored presets on the unit and reverts to the factory presets provided by Line 6 in the latest installed firmware. Variax Electric and Acoustic Guitars and Basses You will have to connect your VARIAX to the WORKBENCH, POD XT/X3 LIVE, or VETTA II to reset your factory default settings. Then you will have to connect your interface to your computer. Here are the instructions for each: Variax Electric 300, 500, 600, 700 and James Tyler Variax Guitars These instruments can only be returned to factory reset by reinstalling the flash memory. Connect the Variax digital guitar cable to your Variax interface (you will need to have the unit powered the with TRS cable unless you are using a POD XT/X3 Live or Vetta) to the Line 6 Monkey, select your variax instrument, choose firmware (in the updates tab), and select "reinstall latest". Variax Reflash and Software update F.A.Q. Variax Acoustic (Steel String and Nylon) 300 These instruments do not have a reset function. The presets are simply a variety of settings that the user can overwrite. In other words, the user cannot lose anything, except for the original settings that are provided as examples/starting points. Variax Acoustic 700 - Soft Reset Start with unit off (TRS cable and/or Variax Digital cable unplugged from guitar). Rotate the model selector to the SITAR position. Press and hold model selector (as in Save routine) while inserting TRS cable or Variax Digital cable to power up the unit and perform reset. For a full reset, please follow the Variax Electric Guitar procedure as described above. Variax Bass 700 705 Factory defaults must be restored one at a time. Select the Model you wish to normalize. Place the blend and two tone controls in the detent position. Now press the Model select pot down until the indicator light stops flashing. The Model should now be restored to factory settings. Use this procedure for any model you want to restore to the factory setting. Vetta I & II Soft Reset: Press the save button, and spin the Page knob until you get "Reset USER memory?". Press the Save button again and you will see the Vetta count through the channels one by one. Hard reset: Vetta Reflash procedures Rackmounted Pro Effect units
  2. We're sure you'll have a great experience with your Helix. As with anything, be sure to regularly back up your presets, and in the event anything unexpected happens while using your Helix, please perform one or more of the steps below while powering on your unit. If your Helix ends up in a bad state due to a failed firmware update try rebooting the Helix/Helix Rack while entering update mode by holding down footswitches 6+12 (Helix/LT) or encoders 1+6 (Rack). You should see "Entered Update Mode" on the screen, once this is done properly. Then you can re-connect to Line 6 Updater. You may need to manually resume the update using Line 6 Updater (NOT HX Edit). Make sure all other recording software is closed on your system. Make sure to try this out on different USB ports, or multiple computers in case of poor USB connections, or if the the Helix doesn't connect at all with update mode, or its regular boot-up. Further info on the update process can be found here: Helix Floorboard/LT 1. Holding footswitch 5+6 on boot restores Global parameters 2. Holding footswitch 7+8 on boot restores presets and setlists ”THIS WILL OVERWRITE ALL USER PRESETS AND SETLISTS 3. Holding footswitch 8+9 on boot restores presets, setlists, and IRs ”THIS WILL OVERWRITE ALL USER PRESETS AND SETLISTS 4. Holding footswitch 9+10 on boot restores presets, setlists, globals and IRs (restores factory bundle) "THIS WILL OVERWRITE ALL USER PRESETS AND SETLISTS 5. Holding footswitch 10+11 on boot will rebuild your presets in the latest loaded firmware 6. Helix can now restore by clearing only the current preset instead of wiping out all presets. While holding footswitches 11 + 12 7. Helix can now, after firmware 1.06.5, enter update mode manually by holding footswitches 6 + 12 Helix Rack Since the rack doesn't have footswitches, you'll instead hold down a combination of the 6 encoders that are below the main LCD screen as you're booting up. ENC2 & ENC3 - reset globals ENC3 & ENC4 - restore stock presets and setlists ENC4 & ENC5 - restore stock presets, setlists, and IRs ENC5 & ENC6 - reset globals and restore presets, setlists, and IRs (entire factory restore) ENC1 & ENC3 - rebuild all presets ENC1 & ENC5 - clear all presets, setlists, and IRs ENC1 & ENC6 - will enter Update Mode (This feature is only available on firmware v1.06.5 and higher) HX Effects 1. Holding FS3 + MODE - Will clear all Presets and IRs 2. Holding FS4+FS5 - Will reset Global Settings 3. Holding FS5+FS6 - Will reset Presets only 4. Holding FS6+TAP - Will Perform factory restore (reset, Globals, IRs, and Presets) 5. Holding the right arrow ">" Will put the unit in a fail safe update mode. Use this when the HX Effects is in a un recoverable state HX Stomp Hold these button combinations while powering up the HX Stomp: 1. FS1, 2 & 3: clears all presets/IRs 2. FS1+2: resets presets and IRs 3. FS 2+3: factory restore (globals, presets, IRs) 4. Page >: update mode. This update mode is helpful if the update is interrupted, and the HX Stomp will not boot properly. You will see a blank screen (no visual feedback on the display). 5. Upper & Lower Knobs: Rebuild presets. Wait for "Will Rebuild Presets..." to appear and let go. HX Stomp XL Hold these button combinations while powering up the HX Stomp XL: 1. FS ^, C & D: clears all presets/IRs 2. FS ^+C: resets presets and IRs 3. FS C+D: factory restore (globals, presets, IRs) 4. Page >: Update mode. This update mode is helpful if the update is interrupted, and the HX Stomp will not boot properly. You will see a blank screen (no visual feedback on the display). 5. Upper & Lower Knobs: Rebuild presets. Wait for "Will Rebuild Presets..." to appear and let go. Make sure to always update to the latest firmware using Line 6 Updater. http://line6.com/software/
  3. Hi- Just updated from 2.82 to 3.01 for Helix floor. All seems to have gone smoothly, but instructions ("Step Tres") say to restore from the backup that was created prior to the update. Everything seems to be OK. Is this restore from backup mandatory for a reason I don't know about or haven't been able to determine? Wouldn't want to retrograde factory settings, for example. Thanks for your input.
  4. Can I restore a single preset from a previous backup? I only see the option for a complete User bank which would wipe out changes made to other presets that I want to keep.
  5. Hi All: Trying to restore the factory defaults (to fix ghost notes in open G tuning) in my Variax Standard. Reflashed to latest FW. Set pickup selector to middle position.Hold down model selector knob. Insert 1/4" plug. Nothing. LEDs don't flash. Any suggestions? Thanks in advance. Buddy
  6. I recently sold my POD XT and the buyer contacted me asking if I had ever "initialized" it. Not sure what he means but it seems he wants to restore it to it's original settings and is having no luck. Any suggestions?
  7. Hi there Since about one year I own a HD500x and use it regularly at home for practice and with a choir, where I play in the accompanying band, mostly at churches. Now my problem is, that the HD500x lies on the ground with all cables plugged in, and if unfortunately e.g. the guitar cable "hangs" over the HD500x, it misadjust the knob position to an unwanted setting (mostly the knobs in the top row, Drive, Bass, Mid etc.), resulting in bad sound. Especially in a live situation, this is really annoying. My solution would be to just reload the saved patch, but I couldn't figure out how to do this when not connected to the computer (there I just copy an empty patch to this slot, but while in a live situation, this is not possible). So, am I the only one that fights with this problem? How would you solve this? Thanks for your help and ideas. erklaerbaer
×
×
  • Create New...